Home

2000i Series AC2729/90 Air Purifier and Humidifier

2000i Series

Air Purifier and Humidifier

Breathe the difference

Philips 2-in-1 purifier cleans rooms up to 65 m² and quickly humidifies the air at a rate of 500 ml/h. With app control and sensors, it scans the air and automatically adjusts to humidify and clean the air of allergens and pollutants.

See all benefits

Unfortunately this product is no longer available

Find similar products

Breathe the difference

Removes 99.97% of particles down to 0.003 microns

  • Purifies rooms up to 65 m²
  • 250 m³/h clean air rate (CADR)
  • 500 ml/h humidification rate
  • Connected with CleanHome+ app

Up to 250 m3/h CADR: Purifiers rooms up to 65 m2

The key performance indicator of a purifier is CADR (Clean Air Delivery Rate): the clean airflow generated in 1 hour. The higher CADR, the faster the cleaning. The dirtier the room, the higher the CADR must be. This purifier has a CADR of 250 m3/h (1) and it can effectively purify a whole room of up to 65 m2 (2).

HEPA filter captures 99.97% of particles of 0.003 microns (3

3-layer filtration with NanoProtect HEPA, active carbon and pre-filter captures 99.97% of ultra-fine particles as small as 0.003 microns (3), so you are safe from PM2.5, bacteria (4), pollen, dust, pet dander, gas and other pollutants.

Removes up to 99.9% of viruses and aerosols from the air

Captures aerosols including those which may contain respiratory viruses. Tested independently by airmid health-group to remove up to 99.9% of viruses and aerosols from the air (5).

NanoCloud technology: hygienic humidification without fuss

Automatic humidification up to 500 ml/h with 4 settings

AeraSense accurately senses and displays air quality

Thoroughly tested for quality you can trust

Sleep mode with ultra-quiet operation

2in1 and purifier-only settings with auto and manual modes

Track and control with the app

Low energy consumption

Technical Specifications
  • Weight and dimensions

    Dimension of packaging (LxWxH)

    445*310*689 mm

    Weight of product

    8.00 kg

    Weight incl. packaging

    9.9 kg

    Dimension of product (LxWxH)

    396*230*580 mm

    Color(s)

    White

    Water tank

    3.5 L

  • Performance

    Filtration

    HEPA, Active Carbon, Prefilter

    CADR (Particle, GB/T) (1)

    250 m³/h

    Humidity rate (8)

    500 ml/h

    Particle filtration (3)

    99.97% at 0.003 microns

    Virus & aerosol filtration (5)

    99.9%

    VitaShield technology

    Yes

    Allergen filtration (10)

    99.97%

    Humidification room size (9)

    Up to 68 m²

    NanoCloud technology (6)

    Up to 99% less bacteria

    Purification room size (2)

    Up to 65 m²

  • CADR: tested by third party according to GB/T 18801-2015
  • Humidification rate: Tested by GB/T 23332 in Philips internal climate chamber, 2017. Chamber size 25m2, initial temperature of 20±2°C and relative humidity of 30±3%RH.
  • Microbial Reduction Rate Test conducted at Airmid Healthgroup Ltd. tested in a 28.5m³ test chamber contaminated with airborne influenza A(H1N1).
  • Prevent spreading white dust or wet spots: Independent third-party test Determination of deposition of minerals from liquid droplets on furniture, according to DIN 44973, IUTA e.V. To determine mineral deposits onto furniture from airborne liquid droplets over a period of 3 hours.
  • Professional grade sensor: Benchmark with Grim sensor and comparison with industry infra-red sensor.
  • Reduce bacteria: Tested by Shanghai Institute of Measurement and Testing Technology (SIMT) in 30m3 chamber according to GB21551.3-2010, (Staphylococcus albsp) 8032 as testing bacteria
  • Room size: Calculated according to GB/T18801-2015.
  • Tested on the filter media with NaCl aerosol, classified at 3nm according to DIN71460-1, in 2017 by third party test lab.
  • Tested on the filter media with 1 pass efficiency at 5.33cm/s airflow, in 2017 by third party test lab.
  • Airborne bacteria concentration in a room depends on many factors such as air exchange, room size and configuration.
  • Results are based on the release of the bacterium Staphylococcus albus from the appliance. Sterilized water spiked with said bacterium was used in the water tanks during the tests. (Filters -if available- were removed from appliances).
  • In a room of 20m²: It is a theoretical time for one-time cleaning calculated by dividing its CADR 250m3/h by the room size of 48m3 (assuming the room is 20m² in floor area and 2.4m in height).